| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Primerljivost vrednosti parametrov plinske analize arterijske krvi in plinske analize venske krvi pri kritično bolnem pacientu
Authors:ID Bele, Božidar (Author)
ID Marinšek, Martin (Mentor) More about this mentor... New window
ID Romih, Gregor (Comentor)
Files:.pdf MAG_Bele_Bozidar_2023.pdf (1,11 MB)
MD5: 7F1CD628201B6E128003C45FF35C0CDE
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FZV - Faculty of Health Sciences
Abstract:Uvod: Plinska analiza arterijske krvi je temeljna diagnostična preiskava pri določanju pacientovega metabolnega, kardiovaskularnega in respiratornega stanja, pridobitev vzorca pa predstavlja za pacienta invaziven poseg. Novejši pristopi omogočajo določitev parametrov iz vzorca venske krvi. Namen zaključnega dela je bil ugotoviti primerljivost vrednosti parametrov pH, HCO₃, pCO₂, pO₂, Na, K in Cl med parametri arterijske in venske krvi. Metodologija: Izveden je bil pregled literature. Uporabljena je bila deskriptivna metoda dela z analizo in kompilacijo identificiranih virov. Iskanje je potekalo v podatkovnih bazah CINAHL, PubMed, Cochrane Library, Web of Science in Wiley Online Library. Uporabljen je bil tudi iskalnik Google Scholar. Vključenim raziskavam je bila ocenjena kakovost, ugotovitve pa so bile sintetizirane. Rezultati: Vključenih je bilo 22 raziskav. Venske vrednosti pH, HCO₃ in pCO₂ so primerljive z arterijskimi. Za te parametre se lahko uporablja venski vzorec krvi. Pri določanju Na, K in Cl je potrebna previdnost, saj parametri med seboj niso primerljivi. Odsvetuje se uporaba vzorca venske krvi za določitev vrednosti pO₂. Razprava in zaključek: Vzorec arterijske krvi je primarna izbira za plinsko analizo krvi. Vzorec venske krvi je lahko uporabljen za parametre pH, HCO₃, in pCO₂, pri čemer je pri interpretaciji vrednosti ostalih parametrov potrebna previdnost.
Keywords:plinska analiza krvi, vzorec arterijske krvi, vzorec venske krvi, pacient, primerljivost parametrov
Place of publishing:Maribor
Publisher:[B. Bele]
Year of publishing:2023
PID:20.500.12556/DKUM-84590 New window
UDC:611.018.5:543.27(043.2)
COBISS.SI-ID:160907011 New window
Publication date in DKUM:10.08.2023
Views:726
Downloads:166
Metadata:XML DC-XML DC-RDF
Categories:FZV
:
BELE, Božidar, 2023, Primerljivost vrednosti parametrov plinske analize arterijske krvi in plinske analize venske krvi pri kritično bolnem pacientu [online]. Master’s thesis. Maribor : B. Bele. [Accessed 13 March 2025]. Retrieved from: https://dk.um.si/IzpisGradiva.php?lang=eng&id=84590
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:26.06.2023

Secondary language

Language:English
Title:Comparability of arterial blood gas and venous blood gas analysis parameter values in critically ill patient
Abstract:Introduction: Arterial blood gas analysis represents a fundamental diagnostic test for determining the patient's metabolic, cardiovascular, and respiratory status. Arterial blood sample collection is an invasive intervention. Newer approaches make it possible to determine parameters from a venous blood sample. The aim of this master's thesis was to determine the comparability of pH, HCO₃, pCO₂, pO₂, Na, K, and Cl parameters' values between arterial and venous blood samples. Methodology: A literature review was conducted. A descriptive method was used, along with the analysis and compilation of identified sources. Literature search was conducted in the databases CINAHL, PubMed, Cochrane Library, Web of Science and Wiley Online Library. The Google Scholar search engine was also used. Included studies were assessed for quality and findings were synthesized. Results: 22 studies were included in the final analysis. Venous values of pH, HCO₃ and pCO₂ are comparable to arterial ones. A venous blood sample can be used for these parameters. Precaution must be taken when interpreting Na, K and Cl parameter values, as the parameters were found not comparable between arterial and venous blood samples. The use of a venous blood sample to determine pO₂ is not recommended. Discussion and conclusion: Arterial blood sample is the primary choice for blood gas analysis. A venous blood sample can be used for pH, HCO₃, and pCO₂ parameters, with caution required for interpretation of other parameters.
Keywords:gaseous blood analysis, arterial blood sample, venous blood sample, patient, comparability of parameters


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica