Title:Zamenjava dotrajanega srednjenapetostnega (20 kV) stikalnega bloka : diplomsko delo
Authors:ID Špes, Gregor (Author)
ID Pranjić, Franjo (Mentor) More about this mentor... New window
ID Virtič, Peter (Comentor)
ID Veber, Gorazd (Comentor)
Files:.pdf VS_Spes_Gregor_2023.pdf (2,53 MB)
MD5: 57FA946EABEF494E6E887BF7ACE8CFC6
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FE - Faculty of Energy Technology
Abstract:V diplomskem delu smo se osredotočili na prikaz in opis zamenjave dotrajanega srednjenapetostnega stikalnega bloka. Nalogo smo izvedli na transformatorski postaji 364 – Kajuhova, v Slovenski Bistrici. V primeru naše transformatorske postaje je bila potreba po zamenjavi stikalne opreme zaradi iztrošenosti materialov v stikalnih celicah. Z ukrepom, ki smo ga izvedli, smo poskusili odjemalce oskrbeti z bolj kakovostno in zanesljivo električno energijo. V teoretičnem delu so podrobneje opisane srednjenapetostne stikalne celice, njihov razvoj skozi čas, stari in novi stikalni blok s pripadajočimi komponentami ter varnost uporabnikov. Empirični del zajema opis zamenjave starega stikalnega bloka za novega po korakih in pripadajočo uporabljeno opremo ter upoštevane varnostne protokole pri sami zamenjavi.
Keywords:stikalna celica, stikalni blok, srednja napetost, transformatorska postaja, varnost
Place of publishing:Maribor
Place of performance:Velenje
Publisher:[G. Špes]
Year of publishing:2023
Number of pages:XII, 30 f.
PID:20.500.12556/DKUM-84259 New window
UDC:621.311.42:621.315.17(043.2)
COBISS.SI-ID:159700483 New window
Publication date in DKUM:25.07.2023
Views:497
Downloads:57
Metadata:XML DC-XML DC-RDF
Categories:FE
:
ŠPES, Gregor, 2023, Zamenjava dotrajanega srednjenapetostnega (20 kV) stikalnega bloka : diplomsko delo [online]. Bachelor’s thesis. Maribor : G. Špes. [Accessed 7 April 2025]. Retrieved from: https://dk.um.si/IzpisGradiva.php?lang=eng&id=84259
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:09.05.2023

Secondary language

Language:English
Title:Replacement of worn-out medium-voltage (20 kV) switchgear
Abstract:In the thesis we focused on the display and description of replacement of worn-out medium voltage switchgear. The task was carried out at the transformer station 364 – Kajuhova in Slovenska Bistrica. In the case of our transformer station, the need to replace the switchgear was due to the wear of the materials in the switchgear cells. With the measure we implemented, we tried to supply customers with more quality and reliable electricity. The theoretical part describes in more detail the medium voltage switch cells, their development over time, the old and new switch blocks with associated components and the safety of users. The empirical part includes a description of the replacement of the old switch block for the new one step by step and the associated equipment used and the safety protocols observed during the replacement itself.
Keywords:switch cell, switch gear, medium voltage, transformation station, safety