| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Določanje arzena v titanovem dioksidu
Authors:ID Govejšek, Tamara (Author)
ID Finšgar, Matjaž (Mentor) More about this mentor... New window
Files:.pdf MAG_Govejsek_Tamara_2018.pdf (2,02 MB)
MD5: 7EB05206574DB77AD97417E8ADE30485
PID: 20.500.12556/dkum/7964fe39-1565-4495-b576-2e6b95e75f78
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:Namen magistrskega dela je optimizacija in validacija postopka določanja vsebnosti arzena (As) v titanovem dioksidu (TiO2) po popolnem razklopu z elektrotermično atomsko absorpcijsko spektrometrijo (ETAAS). V prvem delu smo izbrali način priprave preskusnih vzorcev, primeren za vse tipe pigmentnega TiO2 in določili optimalne pogoje izvajanja določitev As v preskusnih raztopinah z ETAAS. Zaprt mikrovalovni dvo-kislinski razklop je omogočal popoln razklop vseh tipov pigmentnega TiO2 brez izgub analita. Pri pogojih delovanja ETAAS smo izbrali količino preskusnega vzorca, vrsto kivete in določili tip in količino modifikatorja ter temperaturni program, ki je omogočal kontroliran nastanek prostih atomov As v stopnji merjenja absorbance brez izgub analita in brez spominskega efekta zaradi nepopolne odstranitve vzorca iz kivete po končani meritvi. Pirolitsko oplaščena grafitna kiveta s ploščico, uporaba modifikatorja Pd/Mg(NO3)2, temperatura sežiga (Tsežiga) 1000 °C, temperatura atomizacije (Tatomizacije) 2300 °C ter uporaba Zeemanove korekcije ozadja, so nam omogočile dovolj točne in natančne določitve As v koncentracijskem območju 1,0–50,0 mg/kg. Dosežena meja določljivosti (LOQ) postopka je bila 1,0 mg/kg. V koncentracijskem območju As 1,0¬¬–10,0 mg/kg smo dosegli natančnost, izraženo kot standardni odmik (s) ponovljivosti, ± 0,09 mg/kg, v območju 11,0–50,0 mg/kg pa kot relativni standardni odmik (RSD) ± 0,05 mg/kg. V celotnem območju določevanja je bila točnost izražena kot izkoristek 80–120 %. Cilj magistrske naloge je bil razviti postopek z mejo zaznavnosti (LOD) nižjo od 3 mg/kg, kar nam je uspelo.
Keywords:As, ETAAS, modifikator, grafitna kiveta s ploščico, titanov dioksid
Place of publishing:Maribor
Publisher:[T. Govejšek]
Year of publishing:2018
PID:20.500.12556/DKUM-70903 New window
UDC:543.632.472(043.2)
COBISS.SI-ID:21791766 New window
NUK URN:URN:SI:UM:DK:P894F9ZH
Publication date in DKUM:06.09.2018
Views:1688
Downloads:195
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FKKT
:
GOVEJŠEK, Tamara, 2018, Določanje arzena v titanovem dioksidu [online]. Master’s thesis. Maribor : T. Govejšek. [Accessed 18 March 2025]. Retrieved from: https://dk.um.si/IzpisGradiva.php?lang=eng&id=70903
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Searching for similar works...Please wait....
Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:18.06.2018

Secondary language

Language:English
Title:Determination of arsenic in titanium dioxide
Abstract:The purpose of the master thesis is optimization and validation of the procedure for determination of arsenic (As) in titanium dioxide (TiO2) after complete decomposition with electrothermal atomic absorption spectrometry (ETAAS). In the first part, we selected the method of preparing test samples suitable for all types of pigmented TiO2 under certain optimal conditions for performing determinations of As in the test solutions with ETAAS. The enclosed microwave digestion allowed the complete digestion of all types of pigmented TiO2 without the loss of analytes. Under the operating conditions of ETAAS, we selected the quantity of the test sample, the type of tube and the type and the amount of the modifier, and the temperature programme that allowed the controlled formation of free As atoms in the absorbance measurement rate, without the loss of analytes and no memory effect due to incomplete removal of the sample from the tube after measurement. A pyrolytically coated graphite tube with a platform, the use of the Pd/Mg(NO3)2 modifier, the ashing temperature of 1000 °C, the atomization temperature of 2300 °C and the use of the Zeeman background correction enabled accurate and precise determination of As in a concentration range 1,0–50,0 mg/kg. The limit of quantification (LOQ) process reached 1,0 mg/kg. In the concentration range 1,0–10,0 mg/kg, the accuracy expressed as the standard deviation (s) of repeatability is ± 0,09 mg/kg and relative standard deviation (RSD) is ± 0,05 mg/kg in the range 11,0–50,0 mg/kg. In the working dynamic range, the accuracy in terms of a recovery was always in the 80–120% interval. The aim of the master's thesis was to develop a process with a limit of detection (LOD) less than 3 mg/kg, which we succeeded.
Keywords:As, ETAAS, modifier, graphite tube with a platform, titanium dioxide


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica