Title:RAZISKAVA VZROKOV ZA DEGRADACIJO HIDROIZOLACIJE STREHE INDUSTRIJSKE HALE PAPIRNICE A-PRINT S PREDLAGANO SANACIJO
Authors:ID Jordan, Mitja (Author)
ID Lubej, Samo (Mentor) More about this mentor... New window
ID Ivanič, Andrej (Comentor)
Files:.pdf VS_Jordan_Mitja_2016.pdf (1,74 MB)
MD5: 0C5752F6EF9897B1D57D19F859342989
 
Language:Slovenian
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FGPA - Faculty of Civil Engineering, Transportation Engineering and Architecture
Abstract:V diplomskem delu smo obravnavali ravno streho, kot najzahtevnejši konstrukcijski element zgradbe, ki jo obravnavamo kot bazen. Ker je ravna streha podvržena izrazitemu toplotnemu delovanju, moramo upoštevati poleg hidroizolacije tudi toplotno izolacijo. Pri izvedbi hidroizolacije pazimo na pravilno izbiro materialov, njihovo vgradnjo in skrbno izvedbo parne zapore. S stališča gradbene fizike delimo ravne strehe v osnovi na tople in hladne strehe. V delu je predstavljena topla ravna streha iz PVC-P hidroizolacije preplastena s poliuretansko hidroizolacijo. Preiskava je pokazala, da sanacija strehe s PVC-P membrano ni bila ustrezno izbrana.. Objekt leži v območju, kjer so pogosta neurja s točo, zato smo za sanacijo strehe izbrali kritino EPDM-Resitrix MB, ki je odporna na točo in ima dolgo življenjsko dobo.
Keywords:Ravne strehe, PVC-P membrane, poliuretanske kritine, parna zapora, toplotna izolacija, natezni preizkus
Place of publishing:Maribor
Publisher:[M. Jordan]
Year of publishing:2016
PID:20.500.12556/DKUM-62283 New window
UDC:624(043.2)
COBISS.SI-ID:20533526 New window
NUK URN:URN:SI:UM:DK:VILFWJIG
Publication date in DKUM:08.09.2016
Views:1374
Downloads:120
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FG
:
JORDAN, Mitja, 2016, RAZISKAVA VZROKOV ZA DEGRADACIJO HIDROIZOLACIJE STREHE INDUSTRIJSKE HALE PAPIRNICE A-PRINT S PREDLAGANO SANACIJO [online]. Bachelor’s thesis. Maribor : M. Jordan. [Accessed 23 April 2025]. Retrieved from: https://dk.um.si/IzpisGradiva.php?lang=eng&id=62283
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Searching for similar works...Please wait....
Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:RESEARCHING THE CAUSES FOR THE DEGRADATION OF WATERPROOFING MATERIALS ON THE ROOF OF THE INDUSTRIAL HALL A-PRINT WITH THE SUGGESTED RESTORATION
Abstract:In this diploma thesis we researched the flat roof, as the most advanced construction element of a building. We regard it similar to a pool. Because this flat roof was subject to extreme heat exposure, we have to research the thermal insulation as well as the waterproofing materials. When waterproofing a roof, we have to be cautious about choosing the right materials, building them in and the right placement of a vapour barrier. Building engineering physics separate two kinds of flat roofs, the cold and the warm roof. The flat roof presented in this diploma thesis is a warm roof, consisting of PVC-P waterproofing membranes, covered with a layer of polyurethane liquid waterproofing material. The research showed that the restoration of the roof with the PVC-P membrane wasn’t adequately chosen. The building is located in a place, where hailstorms are not an uncommon phenomenon, that is why we have chosen to restore the roof with the membrane EPDM – Resitrix MB, that is resistant to hail and has a long lifespan.
Keywords:Flat roofs, PVC-P membranes, polyurethane roofing materials, vapour barrier, thermal insulation, tensile testing