| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Uporaba kivetnih testov za kontrolo odpadnih vod
Authors:ID Okleščen, Mateja (Author)
ID Simonič, Marjana (Mentor) More about this mentor... New window
ID Novak Pintarič, Zorka (Comentor)
Files:URL VS_Oklescen_Mateja_2012.pdf (2,27 MB)
MD5: DC346C67D07DBD8F9CD85C574EFBDCBB
PID: 20.500.12556/dkum/8601d558-090f-40e0-a93c-43f6f9ce932d
 
Language:Slovenian
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:Namen diplomske naloge je, da ugotovimo, ali kivetni testi lahko zamenjajo standardno metodo za kontrolo odpadnih voda na čistilni napravi. Primerljivost metod smo preizkušali z dvema parametroma: KPK (kemijska potreba po kisiku) in NH4-N (amonijev dušik). Različne vzorce odpadne vode smo odvzeli na različnih delih čistilne naprave. KPK odpadne vode smo določili na treh različnih fotometrih WTW S12, Merck Nova 60 in WTW SpectroFlex 6100 ter jih primerjali z rezultati standardne metode. Z izbranim statističnim testom smo preverili primerljivost med različnimi metodami. Rezultati diplomske naloge kažejo, da standardno metodo pri spremljanju učinkovitosti delovanja čistilne naprave lahko nadomestimo s kivetnimi metodami. Za meritve KPK smo največjo primerljivost standardne in kivetne metode dosegli na fotometru WTW S12, večje odstopanje kažejo meritve na fotometrih Merck Nova 60 in WTW SpectroFlex 6100. Dobro primerljivost standardne metode in kivetnega testa NANOCOLOR Ammonium 04 kažejo tudi meritve NH4-N.
Keywords:Odpadne vode, kontrola odpadnih vod, kivetni testi, standardne metode, statistika
Place of publishing:Maribor
Publisher:[M. Okleščen]
Year of publishing:2012
PID:20.500.12556/DKUM-36965 New window
UDC:628.179.2:543(043.2)
COBISS.SI-ID:16698902 New window
NUK URN:URN:SI:UM:DK:SL4FTE7Z
Publication date in DKUM:18.07.2012
Views:2835
Downloads:255
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FKKT
:
OKLEŠČEN, Mateja, 2012, Uporaba kivetnih testov za kontrolo odpadnih vod [online]. Bachelor’s thesis. Maribor : M. Okleščen. [Accessed 17 March 2025]. Retrieved from: https://dk.um.si/IzpisGradiva.php?lang=eng&id=36965
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Searching for similar works...Please wait....
Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:Application of cuvette tests for wastewater control
Abstract:The purpose of the paper was to establish whether cuvette tests could replace the standard methods of wastewater treatment plant control. Wastewater samples were taken from the different places at wastewater treatment plant. We tested the comparability of cuvette tests with the standard methods according to two parametres: COD (chemical oxygen demand) and NH4-N (ammonium). WTW S12 photometer, Merck Nova 60 and WTW Spectro Flex 6100 cuvette tests were selected and compared with standard COD method using statistical test. The results showed the standard COD method can be replaced by cuvette tests. In the case of COD tests, the largest degree of comparability was achieved on the WTW S12 photometer, whilst discrepancies occured during the measurements using Merck Nova 60 and WTW Spectro Flex 6100. NH4-N measurements point to a high degree of comparability of standard method and NANOCOLOR Ammonium 04 cuvettee test as well.
Keywords:Wastewater, wastewater control, cuvette tests, standard methods, statistics.


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica