| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:POTENCIOMETRIČNO DOLOČANJE N-(2-MERKAPTOPROPIONIL)-GLICINA
Authors:ID Očko, Simona (Author)
ID Kolar, Mitja (Mentor) More about this mentor... New window
ID Brodnjak-Vončina, Darinka (Comentor)
Files:.pdf UNI_Ocko_Simona_2010.pdf (2,25 MB)
MD5: E038ABBCE8171863BEC0F30325F9C615
PID: 20.500.12556/dkum/230da11b-6730-45b8-bd75-7ea022ac3257
 
Language:Slovenian
Work type:Undergraduate thesis
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:Diplomsko delo opisuje potenciometrično določanje N-(2-merkaptopropionil)-glicina z uporabo različnih ionoselektivnih elektrod, njihove odzivne čase, ponovljivost, delovno območje, meje določljivosti in uporabnost v pretočni injekcijski analizi(PIA). Pri kemijski obdelavi srebrne žice v živosrebrovem (II)kloridu je na površini nastala siva plast, ki se je v raztopini MPG obarvala rahlo rjavo do rjavo rdeče. Delovno območje Ag/AgMPG elektrode je med 1x10-2 mol/L in 1x10-5 mol/L MPG pri naklonu 49,0 mV/p(MPG). Srebrna žica obdelana v raztopini živosrebrovega (II) klorida in nato potopljena v Na2S je na površini prevlečena s tanko črno plastjo srebrovega sulfida. Delovno območje te elektrode je med 1x10-2 mol/L in 1x10-5 mol/L pri naklonu 58,2 mV/p(MPG). Srebrna žica kemijsko obdelana v raztopini živosrebrovega (II)klorida in nato potopljena v raztopino KI tvori na površini rumenkasto plast srebrovega jodida. Delovno območje Ag/AgI elektrode je med 1x10-2 mol/L in 3x10-5 mol/L pri naklonu 52,7 mV/p(MPG). Tako pripravljene elektrode so primerne za klasične in pretočne potenciometrične meritve.
Keywords:N-(2-merkaptopropionil)-glicin, pretočna injekcijska analiza, ionoselektivne elektrode, potenciometrija
Place of publishing:Maribor
Publisher:[S. Očko]
Year of publishing:2010
PID:20.500.12556/DKUM-14714 New window
UDC:543.554.547.466.22(043.2)
COBISS.SI-ID:14401558 New window
NUK URN:URN:SI:UM:DK:4MB3FL6K
Publication date in DKUM:20.07.2010
Views:3242
Downloads:292
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FKKT
:
OČKO, Simona, 2010, POTENCIOMETRIČNO DOLOČANJE N-(2-MERKAPTOPROPIONIL)-GLICINA [online]. Bachelor’s thesis. Maribor : S. Očko. [Accessed 3 April 2025]. Retrieved from: https://dk.um.si/IzpisGradiva.php?lang=eng&id=14714
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Similar works from other repositories:

No similar works found

Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:POTENTIOMETRIC DETERMINATION OF N-(2-MERCAPTOPROPIONYL)-GLYCINE
Abstract:The study describes potenciometric determination of N-(2-mercaptopropionyl)-glycine (MPG) using different types of electrodes, their response time, their repeatability, working range, detection limit and their use in flow injection analysis (FIA). After the silver electrode was immersed into the solution of mercury (II)chloride, was on the surface gray layer which become slightly brown to brownish red when we immersed electrode into solution of MPG. Working range of Ag/AgMPG electrode is between 1x10-2 mol/L and 1x10-5 mol/L MPG with the slope of 49,0 mV. Sulfide ion-selective electrode was prepared with chemical pretreatment of the silver wire with mercury (II)chloride and solution of Na2S. On the surface thin black layer of silver sulphide was formed. Working range of this electrode is between 1x10-2 mol/L and 1x10-5 mol/L MPG with the slope of 58,2 mV. Silver wire chemically pretreated with mercury (II)chloride and the solution of KI, formed on the surface yellow layer of silver iodide. Working range of the electrode is between 1x10-2 mol/l and 3x10-5 mol/L with the slope of 52,7 mV. Electrodes prepared in such a way can be used in batch and flow injection measurements also for determination of N-(2-mercaptopropionyl)-glycine in real samples.
Keywords:N-(2-mercaptopropionyl)-glycine, flow injection analysis, ion-selective electrodes, potentiometry


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica