| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:The correlation between pain perception among patients with six different orthodontic archwires and the degree of dental crowding
Authors:ID Marković, Evgenija (Author)
ID Ferčec, Janko (Author)
ID Ščepan, Ivana (Author)
ID Glišić, Branislav (Author)
ID Nedeljković, Nenad (Author)
ID Juloski, Jovana (Author)
ID Rudolf, Rebeka (Author)
Files:.pdf Srpski_arhiv_za_celokupno_lekarstvo_2015_Markovic_et_al._The_correlation_between_pain_perception_among_patients_with_six_different_ortho.pdf (258,88 KB)
MD5: BD67C5F5763F0D0C25B205719128C9B9
 
URL http://www.doiserbia.nb.rs/Article.aspx?ID=0370-81791504134M
 
Language:English
Work type:Scientific work
Typology:1.01 - Original Scientific Article
Organization:FS - Faculty of Mechanical Engineering
Abstract:Introduction: Forces generated in orthodontic treatment with fixed appliances create tension and compression zones in the periodontal ligament resulting in a painful experience for patients. In the first phase of orthodontic treatment, when leveling of teeth is needed, nickel-titanium (NiTi) archwires can be completely engaged in brackets, even in the cases of extreme crowding, exerting small forces. There is a great individual variation in the pain perception related to the application of orthodontic forces. Objective: The aim of this study was to investigate the pain perception among patients with dental crowding after insertion of six different NiTi orthodontic archwires as a part of fixed appliances in the first stage of orthodontic treatment. Methods: The study was conducted on a sample of 189 orthodontic patients receiving one of six different either superelastic or heat activated NiTi archwires, in the first phase of orthodontic treatment. Pain perception was evaluated in groups of patients with different degree of crowding. The modified McGill Pain Questionnaire with Visual Analogue Scale was used to evaluate the quality and intensity of pain. Statistical analysis was performed using simple descriptive statistics, and Pearson`s chi-square test with statistical significance of p<0.05. Results: Majority of patients reported pain as discomfort or pressure of moderate intensity caused by chewing or biting, started within 12 hours, carried on for 3-4 days, and decreased over time without self-medication. Conclusion: No correlation was found between pain perception among patients with different types of NiTi archwires and the degree of crowding.
Keywords:nickel-titanium archwires, pain, dental crowding, orthodontics
Publication status:Published
Publication version:Version of Record
Year of publishing:2015
Number of pages:str. 134-140
Numbering:Letn. 143, št. 3/4
PID:20.500.12556/DKUM-60153 New window
ISSN:0370-8179
UDC:620.1:616.314-089.23
ISSN on article:0370-8179
COBISS.SI-ID:18610710 New window
DOI:10.2298/SARH1504134M New window
NUK URN:URN:SI:UM:DK:WGLPWBQ1
Publication date in DKUM:04.08.2017
Views:1293
Downloads:349
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
MARKOVIĆ, Evgenija, FERČEC, Janko, ŠČEPAN, Ivana, GLIŠIĆ, Branislav, NEDELJKOVIĆ, Nenad, JULOSKI, Jovana and RUDOLF, Rebeka, 2015, The correlation between pain perception among patients with six different orthodontic archwires and the degree of dental crowding. Srpski arhiv za celokupno lekarstvo [online]. 2015. Vol. 143, no. 3/4, p. 134–140. [Accessed 23 April 2025]. DOI 10.2298/SARH1504134M. Retrieved from: https://dk.um.si/IzpisGradiva.php?lang=eng&id=60153
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Searching for similar works...Please wait....
Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Srpski arhiv za celokupno lekarstvo
Shortened title:Srp. arh. celok. lek.
Publisher:Srpsko lekarsko društvo
ISSN:0370-8179
COBISS.SI-ID:3378434 New window

Licences

License:CC BY-NC 4.0, Creative Commons Attribution-NonCommercial 4.0 International
Link:http://creativecommons.org/licenses/by-nc/4.0/
Description:A creative commons license that bans commercial use, but the users don’t have to license their derivative works on the same terms.
Licensing start date:09.06.2016

Secondary language

Language:Serbian
Title:Zavisnost između percepcije bola kod pacijenata sa šest različitih ortodontskih žica i teskobe zubnih nizova
Abstract:Uvod: Ortodontske sile kojima se tokom terapije fiksnim aparatima pomeraju zubi dovode do istezanja i kompresije parodontalnih vlakana, te pojave bola kod pacijenata. U prvoj fazi ortodontskog lečenja, kada se zubi nivelišu, žice od legure nikl-titanijuma proizvode relativno malu silu i mogu se potpuno ligirati u slotove bravica, čak i u slučajevima velike teskobe. Postoje veoma velike individualne varijacije u percepciji bola prilikom primene ortodontskih sila. Cilj rada: Cilj istraživanja je bio da se ispita percepcija bola kod osoba s teskobom u zubnim nizovima nakon ligiranja šest različitih ortodontskih žica u sklopu prve faze terapije fiksnim aparatima. Metode rada: Studija je urađena na uzorku od 189 pacijenata kojima je u okviru ortodontskog lečenja fiksnim aparatima bila ligirana jedna od šest različitih superelastičnih ili termo žica od legure nikl-titanijuma. Percepcija bola je procenjivana kod osoba s različitom izraženošću teskobe. Korišćen je modifikovani Makgilov (McGill) upitnik za bol s Vizuelnom analognom skalom radi opisivanja kvaliteta i intenziteta bola. Statistička obrada podataka je obuhvatila deskriptivnu statističku analizu i primenu h2-testa sa statističkom značajnošću od p<0,05. Rezultati: Najveći broj ispitanika je opisao bol kao neprijatnost ili pritisak srednjeg intenziteta izazvan žvakanjem ili dodirom, koji je počinjao do 12 sati od ligiranja žice, trajao je tri-četiri dana i smanjivao se bez primene lekova. Zaključak: Nije utvrđena statistički značajna razlika u percepciji bola kod osoba s različitom izraženošću teskobe zubnih nizova kojima su bile ligirane superelastične i termo žice od legure nikl-titanijuma.
Keywords:nikel titan, bolečina, ortodontija, ortodontski aparat


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica