Title:Non-Newtonian blood flow around healthy and regurgitated aortic valve with coronary blood flow involved
Authors:ID Marn, Jure (Author)
ID Iljaž, Jurij (Author)
ID Žunič, Zoran (Author)
ID Ternik, Primož (Author)
Files:URL http://www.dlib.si/details/URN:NBN:SI:doc-TXWURZFZ
 
Language:English
Work type:Not categorized
Typology:1.01 - Original Scientific Article
Organization:FS - Faculty of Mechanical Engineering
Abstract:Most numerical simulations about aortic valve are discussing about the blood flow through prosthetic valves, therefore this study covers a biological aortic valve. In this paper the simulation of blood flow around the regurgitated valve as well as around the health valve have been investigated and is showing how the regurgitation affects the heart function and coronary blood flow. Furthermore it also covers the coronary blood flow and its affect on the blood motion around the valve and consequently on the possible calcification. The physical problem has been treated for the period of closed valve, because of the regurgitation, which occurs at that time. For this restriction the assumption of non-elastic geometry has been used. Also the non-Newtonian Power Law model for the blood rheology has been used; because of the regions of slowly moving blood. Results are showing that the coronary blood flow does not have a high impact on the blood motion and thus the calcification is more probable as well that the regurgitation has a strong affect on the heart function, like aortic pressure drop, increased left ventricle volume, etc. The calcification reason has also been stated, but needs some further investigation. This paper covers in detail the geometry of computational domain and physics, so the results can be easily repeated.
Keywords:aortna zaklopka, regurgitacija, dinamika tekočin, nenewtonska tekočina
Publisher:= Association of Mechanical Engineers and Technicians of Slovenia et al.
Year of publishing:2012
Number of pages:str. 482-491, SI 94
Numbering:Vol. 58, no. 7/8
PID:20.500.12556/DKUM-52127 New window
UDC:532.5:51
ISSN on article:0039-2480
COBISS.SI-ID:16068118 New window
DOI:10.5545/sv-jme.2010.023 New window
NUK URN:URN:SI:UM:DK:XMZBMHUW
Publication date in DKUM:10.07.2015
Views:1400
Downloads:105
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
MARN, Jure, ILJAŽ, Jurij, ŽUNIČ, Zoran and TERNIK, Primož, 2012, Non-Newtonian blood flow around healthy and regurgitated aortic valve with coronary blood flow involved. Strojniški vestnik [online]. 2012. Vol. 58, no. 7/8, p. 482–491, si 94. [Accessed 15 March 2025]. DOI 10.5545/sv-jme.2010.023. Retrieved from: http://www.dlib.si/details/URN:NBN:SI:doc-TXWURZFZ
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Strojniški vestnik
Shortened title:Stroj. vestn.
Publisher:Zveza strojnih inženirjev in tehnikov Slovenije [etc.], = Association of Mechanical Engineers and Technicians of Slovenia [etc.]
ISSN:0039-2480
COBISS.SI-ID:762116 New window

Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica