Title:OBRATOVANJE VROČEVODNIH KOTLOV BREZ STALNEGA NADZORA V SKLADU S SMERNICAMI TRD 604
Authors:ID Jerlah, Branko (Author)
ID Hribernik, Aleš (Mentor) More about this mentor... New window
Files:.pdf VS_Jerlah_Branko_2010.pdf (930,38 KB)
MD5: EDBC054CCCDB7BDA6223F7F863E7AA51
PID: 20.500.12556/dkum/35d64350-fbe0-47ad-b179-4d9e3215e97e
 
Language:Slovenian
Work type:Undergraduate thesis
Organization:FS - Faculty of Mechanical Engineering
Abstract:S ciljem večje varnosti ter zmanjšanja potrebnega števila ljudi in s tem tudi stroškov za nadzor nad obratovanjem vročevodnih kotlov so bila s smernicami TRD 604 v Nemčiji določena pravila za obratovanje parnih in vročevodnih kotlov brez stalnega nadzora. Ta zahtevajo vgradnjo posebnih varnostnih in regulacijskih elementov, ki prevzemajo nadzor nad delovanjem naprave. Za obratovanje parnih in vročevodnih kotlov brez stalnega nadzora se tudi v Sloveniji kaže velik interes, ki pa v praksi nima ustreznega odziva, saj naša regulativa tovrstnega obratovanja še ne dopušča.
Keywords:Opremiti kotlarno po smernicah TRD 604, avtomatizacija sistema, znižanje stroškov
Place of publishing:Maribor
Publisher:[B. Jerlah]
Year of publishing:2010
PID:20.500.12556/DKUM-15485 New window
UDC:621.18(043.2)
COBISS.SI-ID:14604310 New window
NUK URN:URN:SI:UM:DK:NWL1AQWH
Publication date in DKUM:10.09.2010
Views:3683
Downloads:545
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FS
:
JERLAH, Branko, 2010, OBRATOVANJE VROČEVODNIH KOTLOV BREZ STALNEGA NADZORA V SKLADU S SMERNICAMI TRD 604 [online]. Bachelor’s thesis. Maribor : B. Jerlah. [Accessed 15 March 2025]. Retrieved from: https://dk.um.si/IzpisGradiva.php?lang=eng&id=15485
Copy citation
  
Average score:
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Searching for similar works...Please wait....
Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:OPERATION OF HOT WATER BOILERS WITHOUT MANUAL CONTROL ACCORDING TO TRD 604
Abstract:In order to achieve a higher safety and reduction of personnel as well as supervision costs of steam and hot water boiler operation, regulations for unattended steam and hot water plant operation, so called TRD 604 guidelines, were introduced in Germany. They require an installation of special safety and regulating elements that take over control of the plant operation. There is a big interest in the unattended steam and hot water boiler operation in Slovenia too, however without a proper response in practice because such an operation is not allowed by our legislation yet.
Keywords:higher safety, reduction of personnel, supervision coasts, automate system