Title:Primerjava vpliva hladilnih sredstev R134a in R450A na učinkovitost toplotne črpalke v sušilnem aparatu : diplomsko delo
Authors:ID Volk, Anže (Author)
ID Iljaž, Jurij (Mentor) More about this mentor... New window
ID Marn, Jure (Comentor)
ID Gatarić, Pero (Comentor)
Files:.pdf VS_Volk_Anze_2019.pdf (2,38 MB)
MD5: B42AEEBF4BDCBEDB9CF0AFC95233D0DF
PID: 20.500.12556/dkum/894238a9-3f17-49a7-ac7f-8053a71cce33
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Abstract:V diplomski nalogi, ki smo jo izdelali v sodelovanju s podjetjem Gorenje d.o.o., smo na podlagi rezultatov eksperimentalnega dela analizirali vpliv hladilnih sredstev R134a in R450A na učinkovitost toplotne črpalke v sušilnem aparatu. Napravljenih je bilo več ponovitev eksperimenta iz katerih smo izbrali dve reprezentativni meritvi in ju med sabo primerjali. V rezultate so zajeti vsi merjeni parametri ter izračunane veličine za primerjavo učinkovitosti toplotne črpalke. Ugotovili smo, da je toplotna črpalka s hladilnim sredstvom R450A, pri danih pogojih, energijsko bolj učinkovita. Čas sušilnega cikla pa se napram delovanju toplotne črpalke s hladilnim sredstvom R134a podaljša.
Keywords:toplotna črpalka, sušilni stroj, hladilno sredstvo, R134a, R450A
Place of publishing:Maribor
Place of performance:Maribor
Publisher:[A. Volk]
Year of publishing:2019
Number of pages:IX, 32 f.
PID:20.500.12556/DKUM-74642 New window
UDC:621.577(043.2)
COBISS.SI-ID:23015958 New window
NUK URN:URN:SI:UM:DK:ZMQUOY1C
Publication date in DKUM:18.09.2019
Views:1142
Downloads:113
Metadata:XML RDF-CHPDL DC-XML DC-RDF
Categories:KTFMB - FS
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.
Licensing start date:03.09.2019

Secondary language

Language:English
Title:Comparison of refrigerent R134a and R450A influence on the heat pump performance in a tumble dryer
Abstract:In the thesis, which was made in cooperation with Gorenje d.o.o., we analyzed the influence of refrigerants R134a and R450A on the heat pump performance in a tumble dryer. Comparison of the refrigerants was based on the results of experimental work. Several measurements were carried out, from which we selected two representative measurements and compared them. The results include all measured parameters and calculated values to compare the efficiency of the heat pump. We found that the heat pump unit with refrigerant R450A is more energy efficient. But time of drying cycle in respect to heat pump unit operating with refrigerant R134a is extended.
Keywords:heat pump, tumble dryer, refrigerant, R134a, R450A.