Title:ANALIZA MOŽNOSTI IZKLJUČITVE ČRPALKE HLADILNE VODE KONDENZATORJA NUKLEARNE ELEKTRARNE KRŠKO
Authors:Srpčič, Tadej (Author)
Predin, Andrej (Mentor) More about this mentor... New window
Fike, Matej (Co-mentor)
Files:.pdf VS_Srpcic_Tadej_2019.pdf (2,00 MB)
MD5: 957909BD47F223F452907A52E5D030E2
 
Language:Slovenian
Work type:Bachelor thesis/paper (mb11)
Typology:2.11 - Undergraduate Thesis
Organization:FE - Faculty of Energy Technology
Abstract:V diplomskem delu so opisane ključne komponente sekundarnega in terciarnega kroga Nuklearne elektrarne Krško ter njihovo delovanje. S preračunom oziroma analizo smo želeli ugotoviti, ali bi elektrarna obratovala stabilno, če bi izključili eno črpalko hladilne vode kondenzatorja, in kako bi se pri tem spremenili parametri elektrarne. Analiza je pokazala, da obratovanje z dvema črpalkama s tehničnega vidika ni problematično, z ekonomskega pa nesmiselno, tudi ob idealnih pogojih za celoten termodinamski proces. Zmanjšanje lastne rabe, ki se zgodi ob izklopu črpalke, ne pokrije padca v omrežje oddane moči. Razlog temu je poslabšanje ključnih termodinamičnih parametrov krožnega procesa NEK.
Keywords:terciarni krog, sekundarni krog, kondenzator, črpalka hladilne vode kondenzatorja, Nuklearna elektrarna Krško
Year of publishing:2019
Publisher:[T. Srpčič]
Source:Krško
UDC:621.039.577:621.224-021.362(497.4Krško)(043.2)
COBISS_ID:1024354908 New window
NUK URN:URN:SI:UM:DK:CBFITJWG
Views:480
Downloads:98
Metadata:XML RDF-CHPDL DC-XML DC-RDF
Categories:FE
:
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:AddThis
AddThis uses cookies that require your consent. Edit consent...

Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:06.06.2019

Secondary language

Language:English
Title:ANALYSIS OF POSSIBILITY TO DISCONNECT ONE OF CONDENSER'S CIRCULATING WATER PUMPS IN NUCLEAR POWER PLANT KRŠKO
Abstract:The diploma thesis presents the key components and basic operational principles of Nuclear power plant Krško's secondary and tertiary systems. Calculations and analysis were used to establish whether the operation of the NPP would remain stable if one of the condenser’s circulating water pumps was disconnected and how this would change the NPP parameters. Analyses indicate that operating with two pumps would not be problematic; however, from a commercial perspective, such operation would not make sense, in spite of ideal conditions. The reduction of auxiliary consumption thatoccurs when a pump is turned offnever compensates for the drop of the power generated at the generator. The reason is thedeterioration of key thermodynamic parameters of the NPP Krško cycle.
Keywords:tertiary cooling circuit, secondary circuit, condenser, circulating water pump, Nuclear power plant Krško