| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:How to test the reliability of instruments used in mirotremor horizontal-to-vertical spectral ratio measurements
Authors:ID Tasič, Izidor (Author)
ID Runovc, Franc (Author)
ID Fakulteta za gradbeništvo, prometno inženirstvo in arhitekturo Univerze v Mariboru (Copyright holder)
Files:.pdf Acta_geotechnica_Slovenica_2010_Tasic,_Runovc_How_to_test_the_reliability_of_instruments_used_in_mirotremor_horizontal-to-vertical_spect_unlocked.pdf (201,91 KB)
MD5: CEEE0EFBA88DF0D37A7B493E98B28AD4
PID: 20.500.12556/dkum/efd59275-8e57-4e08-b33f-4352c4ae1333
 
URL http://fgserver3.fg.um.si/journal-ags/2010-2/article-2.asp
 
Language:English
Work type:Scientific work
Typology:1.01 - Original Scientific Article
Organization:FGPA - Faculty of Civil Engineering, Transportation Engineering and Architecture
Abstract:The reliability of a horizontal-to-vertical spectral ratio (HVSR) curve depends on the results obtained by a verified seismological system. Seismic microzonation provides the basis for a site-specific risk analysis and it can be evaluated using the microtremor HVSR method, where the data are recorded using modern seismological systems. Changes in the transfer function of seismological systems affect the HVSR curve and, consequently, also its interpretation, if these changes are not detected and taken into consideration while performing the microtremor spectral calculations. The reliability of the seismic microzonation performed by such a procedure becomes questionable. An algorithm is developed with a two references system, where the influence of the transfer function on the HVSR curve by the tested system can be evaluated without any a-priori knowledge regarding the transfer functions of any of the systems. This approach is applied to a Lennartz Le-3D/5s seismometer and to a TROMINO seismological system, where two Streckeisen STS2 seismometers are used as the reference systems.
Keywords:seismic microzonation, horizontal-to-vertical spectral ratio method, ambient vibrations, microtremor, seismic system transfer function, reliability and calibration of seismic systems
Publication status:Published
Publication version:Version of Record
Year of publishing:2010
Number of pages:str. 16-28
Numbering:Letn. 7, št. 2
PID:20.500.12556/DKUM-70731 New window
ISSN:1854-0171
UDC:534.64
ISSN on article:1854-0171
COBISS.SI-ID:1092191 New window
NUK URN:URN:SI:UM:DK:BE4HLMMK
Copyright:Fakulteta za gradbeništvo, prometno inženirstvo in arhitekturo Univerze v Mariboru
Publication date in DKUM:11.06.2018
Views:1139
Downloads:66
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Acta geotechnica Slovenica
Shortened title:Acta geotech. Slov.
Publisher:Fakulteta za gradbeništvo, prometno inženirstvo in arhitekturo Univerze v Mariboru
ISSN:1854-0171
COBISS.SI-ID:215987712 New window

Secondary language

Language:Slovenian
Title:Preverjanje zanesljivosti instrumentov za beleženje horizontalno-vertikalnega spektralnega razmerja mikrotremorjev
Abstract:Nepreverjeni seizmološki merilni sistemi lahko povzročijo oporečno karto potresne mikrorajonizacije. Karta potresne mikrorajonizacije, ki je namenjena potresno odpornemu načrtovanju, je lahko zasnovana - poleg nekaterih drugih postopkov - na podlagi analize spektralnega razmerja vodoravnih in navpične komponente mikrotremorjev. Mikrotremorje beležimo z modernimi seizmološkimi sistemi. Spremembe v prenosni funkciji seizmološkega sistema, če le-te niso zabeležene in upoštevane, vplivajo na rezultat in s tem tudi na interpretacijo meritve ter tako posledično na zanesljivost celotnega postopka priprave karte potresne mikrorajonizacije. Zato je potrebno seizmološke sisteme primerno verificirati. Razvili smo postopek, kjer s pomočjo dveh referenčnih seizmoloških sistemov preverimo vpliv prenosih funkcij testiranega sistema na krivuljo spektralnega razmerja mikrotremorjev, ne da bi vnaprej poznali prenosne funkcije kateregakoli od sistemov. Postopek smo prikazali na seizmometru Lennartz LE-3D/5s in na seizmoloških sistemu TROMINO, kjer smo za referenčna seizmometra uporabili širokopasovna seizmometra STS-2.
Keywords:potresna mikrorajonizacija, spektralno razmerje med vodoravnima in navpično komponento, vibracije tal, mikrotremor, prenosna funkcija seizmološkega sistema, kalibracija in zanesljivost seizmološkega sistema, mreža potresnih opazovalnic


Collection

This document is a part of these collections:
  1. Acta geotechnica Slovenica

Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica