Naslov: | Determination of penicillamine by batch and flow-injection potentiometry with AgI-based sensor |
---|
Avtorji: | ID Radić, Njegomir (Avtor) ID Komljenović, Josipa (Avtor) ID Dobčnik, Danilo (Avtor) |
Datoteke: | Croatica_Chemica_Acta_2000_Radic,_Komljenovic,_Dobcnik_Determination_of_penicillamine_by_batch_and_flow-injection_potentiometry_with_AgI.pdf (196,90 KB) MD5: 4031B198291A8172DFD2F8278C54A9BB PID: 20.500.12556/dkum/2b6b7b77-d9c0-46c5-95f2-5819e67632b8
http://hrcak.srce.hr/132094
|
---|
Jezik: | Angleški jezik |
---|
Vrsta gradiva: | Delo ni kategorizirano |
---|
Tipologija: | 1.01 - Izvirni znanstveni članek |
---|
Organizacija: | FKKT - Fakulteta za kemijo in kemijsko tehnologijo
|
---|
Opis: | Potentiometric determination of penicillamine (pen) is described based on a batch experiment and flow-injection analysis (FIA) using a chemical sensor with AgI-based membrane. The membrane was prepared by pressing silver salts (AgI, Ag2S) and powdered Teflon. This membrane was incorporated in a multipurpose electrode body for batch measurements, and in a tabular flow-through sensor body for FIA measurements. For batch measurements, the equilibrium potentials recorded with continuous addition of standard penicillamine solution were considered in relation to ▫$lg(c_pen/mol L^-1)$▫. Linear response with slope of 60 mV was obtained in the concentration range from 2.5 x ▫$10^5$▫ mol ▫$L^1$▫ to 1.8 x ▫$10^-2$▫mol ▫$L-1$▫. In using the tubular sensor with a membrane of the same coposition for FIA measurements, the linear response with slope of 59 mV was recorded in the concentration range from 1 x ▫$10^4$▫ mol ▫$L^1$▫ to 1 x ▫$10^-1$▫ mol ▫$L^-1$▫. The response of the applied chemical sensor to penicillamine (designated also as RSH) is explained by the formation of sparingly soluble RSAg in the reaction solution and/or the exposed surface of the sensor. The solubility product ▫$K_s(RSAg)$▫ was determined using experimental values recorded both by batch measurements and by the continuous-flow experiment. The mean value obtained by different measurements and using a membrane of the same composition is ▫$K_s(RSAg)$▫ = (1.4+-0.1) x ▫$10^-20$▫ mol ▫$L-2$▫). |
---|
Ključne besede: | analytical chemistry, batch potentiometry, flow-injection analysis, membrane electrode, tubular sensors, penicillamine |
---|
Status publikacije: | Objavljeno |
---|
Verzija publikacije: | Objavljena publikacija |
---|
Leto izida: | 2000 |
---|
Št. strani: | str. 265-277 |
---|
Številčenje: | Letn. 73, št. 1 |
---|
PID: | 20.500.12556/DKUM-66656  |
---|
ISSN: | 0011-1643 |
---|
UDK: | 543.257 |
---|
COBISS.SI-ID: | 5204502  |
---|
ISSN pri članku: | 0011-1643 |
---|
NUK URN: | URN:SI:UM:DK:YTPWV4B3 |
---|
Datum objave v DKUM: | 05.07.2017 |
---|
Število ogledov: | 1316 |
---|
Število prenosov: | 90 |
---|
Metapodatki: |  |
---|
Področja: | Ostalo
|
---|
:
|
Kopiraj citat |
---|
| | | Skupna ocena: | (0 glasov) |
---|
Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
---|
Objavi na: |  |
---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |