| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document

Title:Analiza sistemske plošče z difuzorjem v sistemu HVAC
Authors:Selič, Mitja (Author)
Marn, Jure (Mentor) More about this mentor... New window
Files:.pdf MAG_Selic_Mitja_2016.pdf (24,00 MB)
 
Language:Slovenian
Work type:Master's thesis (m2)
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Abstract:V magistrski nalogi je predstavljen sistem prezračevanja Airconomy, ki v celovit sistem vključuje prezračevanje, talno ogrevanje ter hlajenje. Posebnost sistema je v tem, da gre za izpodrivno prezračevanje, v katerem je vsa distribucija dovedenega zraka izvedena v sestavi tal. Poudarek naloge temelji na analizi in primerjavi dveh tipov linijskih difuzorjev, in sicer difuzorja LT451, ki ga pri vgradnji v sistem Airconomy kot standardno varianto uporablja podjetje Schütz ter na drugi strani linijski difuzor LD15, ki pa je moja lastna zamisel. Analiza je razdeljena na tri osnovne sklope, in sicer analiza tokovnega polja znotraj difuzorja z dodatnim manjšim delom klimatiziranega prostora, analiza tokovnega in toplotnega polja v sistemski plošči in analiza tokovnega in temperaturnega polja v klimatiziranem prostoru. V nalogi je analizirana primerjava vplivov različnih izvedb difuzorjev na tokovno in temperaturno polje v prostoru.
Keywords:analiza linijskega difuzorja, sistem Airconomy, sistemska plošca, prezracevanje, ANSYS, CFD
Year of publishing:2016
Publisher:[M. Selič]
Source:Maribor
UDC:532.556:628.8(043.2)
COBISS_ID:20279574 Link is opened in a new window
NUK URN:URN:SI:UM:DK:K1X86IWV
Views:707
Downloads:82
Metadata:XML RDF-CHPDL DC-XML DC-RDF
Categories:KTFMB - FS
:
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:AddThis
AddThis uses cookies that require your consent. Edit consent...

Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:ANALYSIS SYSTEM PLATE WITH THE DIFFUSER IN THE HVAC SYSTEM
Abstract:This master thesis is presented Airconomy ventilation system, which includes a comprehensive system of ventilation, under floor heating and cooling. Specialty of this system in the fact that there is a displacement ventilation. All the distribution of supply air is in under floor structure. The focus of this thesis is based on analysis and comparison of the two types of linear diffusers, namely the diffuser LT451, which is installed in a system Airconomy as standard variant of the company Schütz and on the other side of the line diffuser LD15, which is my own idea. The analysis is divided into three main sections, namely the analysis of the flow field inside the diffuser with additional smaller part of the conditioned space, analysis of velocity and temperature fields in the system board and analysis of velocity and temperature field in the conditioned space. The thesis analyzed the comparison of the effects of different implementations diffuser on the flow and temperature fields in the area.
Keywords:analysis liner diffuser, system Airconomy, system board, ventilation, ANSYS CFD


Comments

Leave comment

You have to log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica