| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:VKLJUČITEV KOMPENZACIJE JALOVE MOČI V MALO HIDROELEKTRARNO
Authors:ID Bratina, Sebastijan (Author)
ID Pihler, Jože (Mentor) More about this mentor... New window
ID Ribič, Janez (Comentor)
Files:.pdf VS_Bratina_Sebastijan_2016.pdf (3,31 MB)
MD5: 6ED4A90014708EF37194D9F68F4F8FB4
 
Language:Slovenian
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:Delo obravnava model male hidroelektrarne Podmelec, v katero vključujemo kompenzacijo jalove energije. Zaradi različnih priporočil proizvajalca asinhronskega generatorja in priporočil operaterja distributivnega omrežja je izvedena ocena prenapetosti ob vklopih asinhronskega generatorja in kondenzatorske baterije. Model male hidroelektrarne je izveden v programskem paketu MatLAB/Simulink z modulom Powersys. Izkaže se, da je ugodneje vklopiti asinhronski generator in kondenzatorsko baterijo istočasno, kot ju vklopiti zaporedno.
Keywords:električno omrežje, hidroelektrarna, kompenzacija jalove energije, prenapetosti
Place of publishing:Maribor
Publisher:[S. Bratina]
Year of publishing:2016
PID:20.500.12556/DKUM-61948 New window
UDC:621.311.21(043.2)
COBISS.SI-ID:20140566 New window
NUK URN:URN:SI:UM:DK:MZGMENCL
Publication date in DKUM:09.09.2016
Views:1756
Downloads:165
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:INCLUSION OF REACTIVE POWER COMPENSATION IN SMALL HYDRO POWER PLANT
Abstract:The work deals with the model of the small hydro power plant Podmelec which also includes reactive power compensation. Due to the various recommendations of the manufacturer of induction generator and recommendations of a distribution network operator is an assessment surges at the pit induction generator and capacitor batteries. Model of small hydropower plants is carried out in the program package MATLAB / Simulink and module Powersys. It turns out that it is preferable to turn on the AC generator and the capacitor battery at the same time as they turn on sequentially.
Keywords:electrical grid, hydro power plant, compensation of reactive power, overvoltage


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica