Title:POSKUSNO OBRATOVANJE ČISTILNE NAPRAVE INDUSTRIJSKE ODPADNE VODE IZ PROIZVODNJE KEMIČNIH IZDELKOV
Authors:Papler, Branko (Author)
Simonič, Marjana (Mentor) More about this mentor... New window
Novak Pintarič, Zorka (Co-mentor)
Files:.pdf MAG_Papler_Branko_2014.pdf (5,20 MB)
 
Language:Slovenian
Work type:Master's thesis/paper (mb22)
Typology:2.09 - Master's Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:Namen magistrskega dela je bil predstaviti izvedbo rekonstrukcije industrijske čistilne naprave (ČN) in implementacijo najboljše razpoložljive tehnike (BAT) čiščenja odpadne vode z naprednim oksidacijskim procesom – AOPs H2O2/UV/Fe3+. S projektom idejne zasnove, potrjenim v prvi polovici 2011, so stekli postopki pridobivanja gradbenega dovoljenja. Zardi vpliva na okolje in izvora odpadne vode iz proizvodnje kemičnih izdelkov (galvanskih preparatov), je bil ključni del pridobitev Vodnega soglasja in Okoljevarstvenega dovoljenja glede emisij v vode, izdanih s strani Agencije RS za okolje. Po pridobitvi gradbenega dovoljenja je sledilo enoletno obdobje poskusnega obratovanja industrijske ČN, ko mi je bila zaupana tudi vloga odgovorne osebe za obratovanje ČN. Pripravili smo poslovnik in navodila za obratovanje ČN, obratovalni dnevnik, uvedli smo postopke določanja parametrov čiščenja v internem laboratoriju, vključno s pripravo vzorcev za določanje KPK, ki vsebujejo H2O2. V proizvodnji smo vzpostavili sistem ločenega zbiranja in ponovne uporabe prve izpiralne vode pri čiščenju mešalnih posod. Pri obdelavi odpadne vode s povišanimi vsebnostmi fosfatov smo določili njihov vpliv na zmanjšanje učinkovitosti kemične oksidacije z H2O2/UV/Fe3+ procesom, posledično z nastankom železovega (III) fosfata. Sestava odpadne vode, ki jo je mogoče obdelati v realnem času in s sprejemljivimi stroški, ima vrednosti KPK ≤ 3 000 mg O2/l in celotnega fosforja P ≤ 250 mg P/l. Določili smo deleže znižanja vrednosti KPK kemične oksidacije v dveh reaktorjih z 24 kW in 36 kW UV svetili in končnega čiščenja z mikrofiltracijo in kationsko izmenjavo, s čimer se zagotavljajo predpisane mejne vrednosti za iztok v površinske vode. Izpolnjena sta bila tudi oba osnovna cilja projekta: novembra 2013 smo pridobili uporabno dovoljenje in s čiščenjem odpadne vode na interni ČN nismo povišali obstoječih stroškov.
Keywords:čistilna naprava, industrijska odpadna voda, proces H2O2/UV/Fe3+, kemični izdelki, galvanski preparati
Year of publishing:2014
Publisher:[B. Papler]
Source:Maribor
UDC:628.179.2:628.32(043.2)
COBISS_ID:18243606 Link is opened in a new window
NUK URN:URN:SI:UM:DK:LMMDOGYA
Views:2267
Downloads:349
Metadata:XML RDF-CHPDL DC-XML DC-RDF
Categories:KTFMB - FKKT
:
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:AddThis
AddThis uses cookies that require your consent. Edit consent...

Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:OPERATING OF THE INDUSTRIAL WASTE WATER TREATMENT PLANT FROM CHEMICAL PRODUCTION DURING TRIAL PERIOD
Abstract:The purpose of this master's work was to present the reconstruction of the industrial waste water treatment plant (WWTP) and the implementation of Best available techniques (BAT) of waste water treatment with an Advanced oxidation process – AOPs H2O2/UV/Fe3+. With the project proposal approving in the first half of 2011, the procedures of obtaining an operating permit start to run. Impact on the environment and the origin of the waste water from the production of chemical products (electroplating chemicals) were the key parts of obtaining the consent of the Water and Environmental permit in respect of emissions into water, issued by the Environmental Agency. After obtaining a building permit, one-year of trial period was followed, when I was appointed to be the responsible person for the operation of the WWTP. We prepared the rules of procedure and operating instructions for the WWTP, operating log, we have introduced procedures for determining the parameters of cleaning in internal laboratory, including the preparation of samples for the determination of COD, containing H2O2. In production, we have established a system of separate collection and re-use the first rinse water from cleaning of mixing vessels. In the treatment of waste water with high levels of phosphates, we determine their impact on the reduction in the efficiency of chemical oxidation with H2O2/UV/Fe3+ process, consequently by the formation of iron (III) phosphate. The composition of waste water with COD ≤ 3 000 mg O2/l and total phosphorus P ≤ 250 mg P/l, can be processed in real time and with reasonable cost. We determined the proportions of COD decrease by chemical oxidation in two reactors with UV lighting 24 kW and 36 kW and final cleaning with microfiltration and cationic exchange, which ensures the prescribed limits for discharge in-to surface waters. We were also reach two basic objectives of the project: in November 2013 we acquired the operating permit and waste water treatment at the internal WWTP did not increase the existing costs.
Keywords:waste water treatment plant, industrial waste water, process H2O2/UV/Fe3+ chemical products, electroplating chemicals