Title:PREVERJANJE PRAVILNE UPORABE TEHNOLOGIJE 12-KANALNEGA SNEMANJA EKG SIGNALA V KLINIČNEM OKOLJU
Authors:Jaušovec, Nina (Author)
KRIŽMARIĆ, MILJENKO (Mentor) More about this mentor... New window
Files:.pdf VS_Jausovec_Nina_2013.pdf (11,24 MB)
 
Language:Slovenian
Work type:Undergraduate thesis (m5)
Typology:2.11 - Undergraduate Thesis
Organization:FZV - Faculty of Health Sciences
Abstract:V diplomskem delu smo preverjali odstopanja od pravilne postavitve prekordialnih EKG elektrod. Ugotavljamo, da je tudi pri nas pomanjkljivo znanje s področja snemanja EKG, za kar so odgovorne medicinske sestre. Ugotovili smo, da na pravilno postavitev EKG elektrod ne vpliva spol zdravstvenih delavcev, izobrazba, prav tako tudi delovne izkušnje. Največ napak je bilo ugotovljenih pri postavitvi C1 in C2 elektrode. Ugotovili smo, da EKG posnetki pri zdravih prostovoljcih z napačno postavitvijo elektrod izstopajo in so vidni v vseh šestih odvodih. Ugotavljamo tudi, da se posnetek s simulatorjem popolnoma ujema z posnetkom EKG na prostovoljcih.
Keywords:elektrokardiogram, elektrokardiografija, prekordialni odvodi, unipolarni odvod, bipolarni odvod
Year of publishing:2013
Publisher:[N. Jaušovec]
Source:Maribor
UDC:616.12-073.7
COBISS_ID:1984164 Link is opened in a new window
NUK URN:URN:SI:UM:DK:6P23K0QA
Views:3515
Downloads:843
Metadata:XML RDF-CHPDL DC-XML DC-RDF
Categories:FZV
:
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:AddThis
AddThis uses cookies that require your consent. Edit consent...

Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:VERIFYING THE CORRECT APPLICATION OF THE TECHNOLOGY FOR THE 12-CHANNEL ECG SIGNAL IN A CLINICAL SETTING
Abstract:In the thesis, we examined deviations from the proper placement of precordial ECG electrodes. We learned that even knowledge of the ECG is the responsibility of the nurse, gender, health, education and work experience. Most errors were detected by setting C1 and C2 electrodes. In healthy volunteers, we found that ECG recordings, the wrong electrode line ups stood out and could be seen in all six leads. We also noted that the recordings of the simulator are fully consistent with the ECG recordings on volunteers.
Keywords:ECG, electrocardiogram, precordial leads, unipolar leads, bipolar leads