Title:SENZORSKI SISTEM ZA UGOTAVLJANJE ONESNAŽENOSTI ZRAKA
Authors:Hohnec, Damjan (Author)
Hadžiselimović, Miralem (Mentor) More about this mentor... New window
Igrec, Dalibor (Co-mentor)
Files:.pdf VS_Hohnec_Damjan_2012.pdf (5,54 MB)
 
Language:Slovenian
Work type:Bachelor thesis/paper (mb11)
Typology:2.11 - Undergraduate Thesis
Organization:FE - Faculty of Energy Technology
Abstract:Diplomsko delo opisuje izdelavo senzorskega sistema za ugotavljanje onesnaženja zraka. Z nizkocenovnimi senzorji se merijo koncentracije naslednjih plinov: dušikovega oksida, dušikovega dioksida, žveplovega dioksida, ogljikovega monoksida, ogljikovega dioksida, kisika in metana. Signali s senzorjev so obdelani z vezji za kondicioniranje signalov. Signali se zajemajo z analogno-digitalnim pretvornikom mikrokrmilnika. Podatki se prikazujejo na LCD-prikazovalniku in se pošiljajo na računalnik. Za zajem podatkov z računalnikom je program implementiran v programskem okolju Labview, ki koncentracije prikazuje na grafih. Opravljena je kalibracija senzorjev z referenčnimi testnimi plini na Elektroinštitutu Milana Vidmarja.
Keywords:plinski senzor, elektrokemijski senzor, onesnaženost zraka, merilni sistem, senzorski sistem, dušikov oksid, dušikov dioksid, žveplov dioksid, ogljikov monoksid, ogljikov dioksid, kisik, metan, mikrokrmilnik, Bascom, Labview
Year of publishing:2012
Publisher:[D. Hohnec]
Source:Krško
UDC:681.581:502(043.2)
COBISS_ID:1024103260 Link is opened in a new window
NUK URN:URN:SI:UM:DK:FGPPIQ51
Views:1855
Downloads:245
Metadata:XML RDF-CHPDL DC-XML DC-RDF
Categories:FE
:
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:AddThis
AddThis uses cookies that require your consent. Edit consent...

Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:SENSOR SYSTEM FOR AIR POLLUTION DETECTION
Abstract:Diploma work descibes development of a sensor system for air pollution detection. The concentration of gases nitric oxide, nitrogen dioxide, sulphur dioxide, carbon monoxide, carbon dioxide, oxigen and methane is being measured with low-cost sensors. The signals from sensors are processed through signal conditioning electronic circuits. Signals are acquired with an analog to digital converter of a microcontroller. The data is being represented on an LCD module and sent to a computer. Programme developed in Labview reads concentrations and displays them on graphs. Sensors have been calibrated at Milan Vidmar Electric Power Research Institute.
Keywords:gas sensor, electrochemical sensor, air pollution, measuring system, sensor system, nitrogen oxide, nitric dioxide, sulphor dioxide, carbon monoxide, carbon dioxide, oxigen, methane, microcontroller, Bascom, Labview