Abstract: The recently developed European flaw assessment procedure SINTAP was applied to the failure analysis of a broken fork of a forklift. Based on the service load at failure, critical crack sizes were determined at different analysis levels of the procedure. It was shown in the present case study that the failure was caused by defective design.Keywords: structural integrity, mechanics of structures, forklift, fracture mechanics, critical crack size, failure analysis, SINTAP procedure, load bearing capacityPublished in DKUM: 01.06.2012; Views: 2294; Downloads: 94 Link to full text