Abstract: In this paper an improved measurement system for experimental assessment of magnetic fluid losses is presented. When fluid is exposed to AC magnetic field, three different losses mechanisms are active; relaxation, hysteresis and resonance mechanism. In this paper not individual contributions where studied but combine acting which can be determine as specific power losses (SPL). SPL of the sample is obtained for a variety of amplitudes and frequencies of magnetic field with presented method of measurement of field parameters where results revealed f H2 dependence for fixed temperature of the sample. Temperature dependence of SPL is examined with calorimetrical measurements, where heating of magnetic fluid at fixed value of applied field and various frequencies is examined and results revealed linearly decreasing temperature dependence.Keywords: magnetic fluid loss, magentic field, hysteresis loopPublished in DKUM: 30.06.2017; Views: 1465; Downloads: 419 Full text (495,15 KB)This document has many files! More...