| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Search the digital library catalog Help

Query: search in
search in
search in
search in
* old and bologna study programme

Options:
  Reset


1 - 10 / 13
First pagePrevious page12Next pageLast page
1.
2.
Določevanje težkih kovin v zelenjavi z ICP-MS : diplomsko delo univerzitetnega študijskega programa I. stopnje
Lučka Godec, 2024, undergraduate thesis

Abstract: V diplomskem delu smo izvedli delno validacijo metode za simultano določevanje 18 težkih kovin (Al, As, Ba, Cd, Co, Cr, Cu, Fe, Ga, Mn, Mo, Ni, Pb, Se, Sn, Sr, Tl in Zn) v 54 vzorcih zelenjave z induktivno sklopljeno plazmo z masno spektrometrijo. Določili smo mejo zaznavnosti, mejo določljivosti, linearno koncentracijsko območje, točnost in natančnost. Vzorce zelenjave smo posušili, homogenizirali in nato izvedli popoln mikrovalovni razklop. Določili smo vsebnost težkih kovin v ng/g suhe mase zelenjave in te vsebnosti primerjali z zgornjimi mejnimi vrednostmi določenimi s strani mednarodnih organizacij, ki delujejo na področju prehrane. Vzorce zelenjave smo pridobili iz dveh različnih krajev (Maribora in Slovenj Gradca) v dveh različnih trgovinah (trgovina A in trgovina B), kjer smo primerjali zelenjavo tako slovenskega kot tujega izvora. Primerjali smo tudi zelenjavo z domačega vrta in zelenjavo, kupljeno v že omenjenih trgovinah. Ugotovili smo, da največ zgornjih mejnih vrednosti presega bučka iz Španije. Za Ba je bila izmed vseh težkih kovin v različnih vzorcih zelenjave največkrat presežena zgornja mejna vrednost. Vsebnost As je dvakrat presegla zgornjo mejno vrednost, in sicer v čebuli nizozemskega porekla kupljeni v trgovini A v Slovenj Gradcu in čebuli avstrijskega porekla, kupljeni v trgovini B v Slovenj Gradcu. Za Cd je bila v 5 vzorcih zelenjave presežena zgornja mejna vrednost, od tega so bili 3 vzorci z domačega vrta, 2 pa kupljena v trgovini A v Mariboru in trgovini B v Mariboru. Vsebnosti Pb in Sn nismo kvantitativno določili v nobenem vzorcu zelenjave.
Keywords: Težke kovine, zelenjava, homogenizacija, mikrovalovni kislinski razklop, ICP-MS
Published in DKUM: 16.09.2024; Views: 23; Downloads: 55
.pdf Full text (6,16 MB)

3.
Razvoj metod za določanje organskih molekul z uporabo modificiranih in nemodificiranih sitotiskanih ogljikovih elektrod : doktorska disertacija
David Majer, 2024, doctoral dissertation

Abstract: Kvalitativna in kvantitativna analiza organskih molekul v različnih vzorcih je ključnega pomena za zagotavljanje varnosti, učinkovitosti, skladnosti z zakonodajo in kakovostjo na področjih okoljskega varstva, zdravstva ter živilske in farmacevtske industrije. V doktorski disertaciji so predstavljene novo razvite elektroanalizne metode z nemodificiranimi in modificiranimi sitotiskanimi ogljikovimi elektrodami (SPCE) za določanje epinefrina (EP), sečne kisline (UA), metil parationa (MP) in inzulina (IN) v različnih realnih vzorcih, kot so zdravila, človeški urin in pitna voda. Pri prvi razviti metodi smo pokazali individualno določanje EP in UA, ki je potekalo z nemodificiranim SPCE-senzorjem, kjer smo razvili elektroanalizno metodo z analizo ene kapljice raztopine (50 µL). Linearni regresijski model smo ovrednotili z uteženo metodo najmanjših kvadratov, ki je izboljšala točnost pri nizkih koncentracijah linearnega koncentracijskega območja za oba analita v primerjavi z metodo najmanjših kvadratov. Razviti in validirani metodi sta bili uspešno uporabljeni za določanje EP v zdravilu (injekcijski peresnik) in UA v človeškem urinu. Razvoj druge elektroanalizne metode smo izvedli tako, da smo z L-cisteinsko kislino (LCA) modificirali površino SPCE-senzorja (LCA-SPCE), kar je omogočilo določanje pesticida MP v vzorcu pitne vode. Uspešno elektronalaganje LCA na površino delovne elektrode LCA-SPCE-senzorja smo potrdili s tehniko masne spektrometrije sekundarnih ionov z analizatorjem na čas preleta (ToF-SIMS). Prisotnost LCA na površini delovne elektrode SPCE-senzorja je signifikantno povišala signal tehnike angl. square-wave (SW) voltametrije, kar omogoča določanje MP v sledovih. Razvita metoda je vključevala postopek odštevanja ozadja, ki je pripomogel k povišanju analitskega signala. S tehniko elektrokemijske impedančne spektroskopije smo pojasnili povišanje signala MP na LCA-SPCE-senzorju. Pri razvoju tretje elektroanalizne metode smo na površino SPCE-senzorja naložili poli-L-cisteinsko (pLC)-plast in ta pLC-SPCE-senzor uporabili za simultano določanje EP in UA. Uspešno elektronalaganje L-cisteina (LC) na površino delovne elektrode SPCE-senzorja smo potrdili s tehniko ToF-SIMS. Za ta senzor smo izvedli optimizacijo različnih SW-parametrov (amplituda, potencialni korak, frekvenca), pH pomožnega elektrolita, čas elektronalaganja, potencial elektronalaganja, množinske koncentracije LC in števila ciklov elektropolimerizacije LC z namenom dosega najboljše elektroanalizne zmogljivosti pLC-SPCE-senzorja. Pod optimiziranimi pogoji smo izvedli validacijo analizne metode za simultano določanje EP in UA. Prav tako smo izvedli študijo interferenc, ki so lahko potencialno prisotne v testiranih realnih vzorcih. Razvit in validiran pLC-SPCE-senzor smo uspešno uporabili za določanje EP v injekcijskem peresniku in UA v človeškem urinu. V četrti študiji smo razvili elektroanalizno metodo za določanje klinično pomembnega biomarkerja IN. Uporabili smo SPCE-senzor, ki smo ga modificirali z molekularno vtisnjenim polimerom (MIP). Razvoj MIP-SPCE-senzorja je potekal tako, da smo najprej elektropolimerizirali pirol v prisotnosti IN. Nato smo iz nastale polipirolne plasti odstranili molekule IN in s tem tvorili praznine z vezavnimi mesti za molekule IN. Odstranjevanje IN smo izvedli s pomočjo elektročiščenja s ciklično voltametrijo. Nato je sledila inkubacija molekul IN, ki so se vezale na tvorjena vezavna mesta na MIP-SPCE-senzorju. Določanje IN z razvitim MIP-SPCE-senzorjem je potekalo z analizo ene kapljice raztopine, ki je vsebovala redoks probo [Fe(CN)6]3‒/4‒. Elektroanalizno metodo z razvitim MIP-SPCE-senzorjem smo validirali in pokazali njeno uporabo za določanje IN v zdravilu (injekcijski vložek).
Keywords: epinefrin, sečna kislina, metil paration, inzulin, sitotiskana ogljikova elektroda, senzor
Published in DKUM: 27.06.2024; Views: 223; Downloads: 112
.pdf Full text (25,18 MB)

4.
5.
The development of an electropolymerized, molecularly imprinted polymer (MIP) sensor for insulin determination using single-drop analysis
Tanja Zidarič, David Majer, Tina Maver, Matjaž Finšgar, Uroš Maver, 2023, original scientific article

Abstract: An electrochemical sensor for the detection of insulin in a single drop (50 μL) was developed based on the concept of molecularly imprinted polymers (MIP). The synthetic MIP receptors were assembled on a screen-printed carbon electrode (SPCE) by the electropolymerization of pyrrole (Py) in the presence of insulin (the protein template) using cyclic voltammetry. After electropolymerization, insulin was removed from the formed polypyrrole (Ppy) matrix to create imprinting cavities for the subsequent analysis of the insulin analyte in test samples. The surface characterization, before and after each electrosynthesis step of the MIP sensors, was performed using atomic force microscopy, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. The performance of the developed MIP–SPCE sensor was evaluated using a single drop of solution containing K3Fe(CN)6 and the square-wave voltammetry technique. The MIP–SPCE showed a linear concentration range of 20.0–70.0 pM (R2 = 0.9991), a limit of detection of 1.9 pM, and a limit of quantification of 6.2 pM. The rapid response time to the protein target and the portability of the developed sensor, which is considered a disposable MIP-based system, make this MIP–SPCE sensor a promising candidate for point-of-care applications. In addition, the MIP–SPCE sensor was successfully used to detect insulin in a pharmaceutical sample. The sensor was deemed to be accurate (the average recovery was 108.46%) and precise (the relative standard deviation was 7.23%).
Keywords: electrochemical sensors, electropolymerisation, electron microscopy
Published in DKUM: 14.03.2024; Views: 335; Downloads: 42
.pdf Full text (2,91 MB)
This document has many files! More...

6.
Navodila za laboratorijske vaje pri predmetu Elektrokemijske metode
David Majer, Barbara Rajh, Matjaž Finšgar, 2023, other educational material

Keywords: elektrokemija, laboratorijske vaje, kemija
Published in DKUM: 16.01.2024; Views: 500; Downloads: 46
.pdf Full text (9,19 MB)

7.
A comparison of analytical techniques for the determination and monitoring of charge variants in therapeutic proteins : master's thesis
Eva Kropušek, 2023, master's thesis

Abstract: Charge variants of therapeutic proteins are considered to be drug product variants and process-related impurities. To monitor charge heterogeneity, the development of a new analytical method is needed. Imaged capillary isoelectric focusing, capillary zone electrophoresis, and cation exchange chromatography assays were evaluated as candidate assays to support the early development of two new biological drug candidates. These are the analytical techniques most frequently used in the pharmaceutical industry for monitoring charge heterogeneity. We compared the advantages and disadvantages of these analytical techniques for monitoring charge variants in two innovative monoclonal antibodies. The results obtained revealed similarities and differences in the various analytical techniques. However, there is only a short time-frame dedicated to analytical method development when developing new biological drugs. With this in mind, imaged capillary isoelectric focusing showed a perfect balance between the quality and speed of analysis.
Keywords: Imaged capillary isoelectric focusing, capillary zone electrophoresis, cation exchange chromatography, charge variants, biological drug
Published in DKUM: 03.10.2023; Views: 638; Downloads: 41
.pdf Full text (3,02 MB)

8.
Validacija metod za ovrednotenje prenosa analita avtomatskega sistema dissoBOT za teste raztapljanja farmacevtskih učinkovin in optimizacija cikla čiščenja : magistrsko delo
Aljaž Šporin, 2023, master's thesis

Abstract: V magistrskem delu smo določali prenos analita (CO, angl. carry over) avtomatiziranega sistema za izvajanje testov raztapljanja dissoBOT, kjer smo kot aktivni farmacevtski učinkovini (API) uporabili paracetamol (PA) in natrijev diklofenak (ND). Za oba API-ja smo izvedli delno validacijo spektrofotometrične metode UV-VIS, kjer smo preverjali mejo zaznavnosti (LOD) in mejo določljivosti (LOQ), linearno koncentracijsko območje, točnost in natančnost. Vrednosti LOD za oba API-ja so bile manjše od 0,01 mg/L. Za PA smo določili linearno koncentracijsko območje od 1,00‒30,00 mg/L, za ND pa od 0,50‒3,50 mg/L (v obeh primerih je bil kvadrat korelacijskega koeficienta večji od 0,9990 in koeficient kvalitete <1,00 %). Točnost metod smo ovrednotili z izračunom izkoristka raztopin standardov z znano koncentracijo in ju potrdili za oba API-ja (povprečni izkoristek je bil za PA 99,81 % in za ND 101,43 %). Natančnost smo ovrednotili z izračunom relativnega standardnega odmika (RSD). Obe metodi sta bili natančni z vrednostjo RSD 0,13 % za PA in 0,38 % za ND. Optimizirali smo volumen pralnega medija v obeh ciklih čiščenja, ki ju izvede sistem dissoBOT, in odmerjanje medija, kjer je dovoljeno odstopanje določeno z zahtevami Ameriške farmakopeje. Prav tako smo določili vpliv volumna (V) cikla čiščenja avtomatskega vzorčevalnika 850-DS, ki je eden izmed treh instrumentov, ki sestavljajo sistem dissoBOT, na vrednost CO. CO sistema dissoBOT, kjer je bil kot čistilni medij uporabljena voda iz pipe, je bil v primeru uporabe PA in ND nižji od 1,00 %. Določili smo vpliv V cikla čiščenja vzorčevalnika 850-DS na CO, kjer je bila vrednost CO pri V cikla čiščenja vzorčevalnika 850-DS 2 mL 1,38 %, pri V 5 mL 0,86 % in pri V 10 mL 0,32 %. CO pri V cikla čiščenja vzorčevalnika 850-DS 10 mL in dveh izvedenih ciklih čiščenja je bil manjši od 0,20 %.
Keywords: prenos analita, avtomatizacija, validacija, dissoBOT, testi raztapljanja, UV-VIS
Published in DKUM: 04.05.2023; Views: 603; Downloads: 87
.pdf Full text (8,39 MB)

9.
Določevanje težkih kovin v pijačah z ICP-OES : magistrsko delo
Ela Likovnik, 2023, master's thesis

Abstract: Magistrsko delo prikazuje delno validacijo tehnike induktivno sklopljene plazme z optično emisijsko spektroskopijo (ICP-OES) za določevanje ionov As, Ba, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Sr in Zn v vzorcih pijač. Delno validacijo smo za vsak analit izvedli pri več valovnih dolžinah in med njimi izbrali eno valovno dolžino za vsak analit glede na zastavljen kriterij. Določili smo mejo zaznavnosti (LOD), mejo določljivosti (LOQ), linearno koncentracijsko območje, točnost in natančnost. Linearno koncentracijsko območje metode smo ovrednotili z izračunom kvadrata korelacijskega koeficienta (R2) in koeficienta kvalitete (QC), zastavljena kriterija sta bila R2 ≥ 0,9990 in QC ≤ 5,00 %. Natančnost smo ovrednotili z izračunom relativnega standardnega odmika, ki je bil za vse analite manjši od zastavljenega kriterija 20,0 %. Točnost metode smo potrjevali z izračunom izkoristkov meritev raztopin standarda znane koncentracije. Izkoristki so bili znotraj zastavljenega kriterija med 80,0 % in 120,0 %. Točnost določevanja koncentracije ionov kovin v vzorcih pijač smo preverili z izračuni izkoristkov, pri čemer smo vzorcem pijač dodali znano količino raztopine standarda. Slednjo točnost smo potrdili za vse ione kovin v vzorcih pijač znotraj zastavljenega kriterija. Vzorce pijač smo pred analizo z ICP-OES pripravili s pomočjo mikrovalovnega kislinskega razklopa v raztopini HNO3 in H2O2. Instrument smo pred merjenjem vzorcev pijač umerili in ga na vsakih 23 injiciranj ponovno umerili. Na ta način smo opazovali, kako se signal spreminja s številom injiciranj ter določili, na koliko injiciranj je potrebno narediti ponovno umerjanje instrumenta za določen analit. Ioni Se so bili edini ioni, ki jih nismo zaznali v nobenem od 25 testiranih vzorcev pijač (ali ionov Se ni bilo v vzorcih ali pa je bila koncentracija pod LOD). Ione Co smo zaznali v enem, Pb v štirih, As v desetih in Mo v enajstih vzorcih pijač, vendar jih ni bilo mogoče kvantificirati, saj so bile izmerjene koncentracije pod LOQ. Izmerjene vsebnosti ionov kovin v vzorcih pijač smo primerjali z mejnimi vrednostmi za vsebnost ionov kovin v pitni vodi, določenimi s strani Svetovne zdravstvene organizacije, Evropske agencije za varnost hrane in v Pravilniku o pitni vodi (Uradni list RS št. 19/2004). Previsoko vsebnost smo določili le pri merjenju vsebnosti ionov Mn v vzorcu ananasovega soka. Ioni kovin, ki smo jih določiti v ostalih vzorcih pijač, so bili pod mejnimi vrednostmi in posledično lahko trdimo, da uživanje analiziranih pijač ne predstavlja tveganja za zdravje.
Keywords: ICP-OES, mikrovalovni kislinski razklop, delna validacija metode, težke kovine, kovine v pijačah
Published in DKUM: 31.03.2023; Views: 758; Downloads: 134
.pdf Full text (1,87 MB)

10.
Določanje težkih kovin v mesu, mesnih izdelkih in morski hrani z ICP-OES : magistrsko delo
Nika Proje, 2022, master's thesis

Abstract: Magistrsko delo prikazuje izvedbo delne validacije metode za določanje As, Ba, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Sr in Zn v vzorcih mesa, mesnih izdelkov in morske hrane z uporabo induktivno sklopljene plazme z optično emisijsko spektroskopijo, pripravo in mikrovalovni kislinski razklop vzorcev ter določanje izbranih kovin v njih. Za vsako testirano kovino smo določili meji zaznavnosti in določljivosti. Z izračunom kvadratov korelacijskih koeficientov umeritvenih premic, večjih od 0,990, smo potrdili linearnost v izbranem koncentracijskem območju. Z izračuni izkoristkov meritev raztopin standarda znane koncentracije, ki so bili znotraj kriterija med 80 % in 120 %, smo potrdili točnost. Točnost smo nato preverili še s testiranjem izkoristkov realnega vzorca, ki smo mu dodali znano količino raztopine standarda, in jo potrdili za večino kovin, razen za Sr. Z izračuni relativnih standardnih odmikov meritev raztopine standarda, manjših od 20 %, smo potrdili natančnost (ponovljivost). Opazovali smo, kako se signal ICP-OES instrumenta spreminja s številom injiciranj ter določili, po koliko injiciranjih je potrebno ponovno umerjanje instrumenta. V vseh vzorcih smo določili kakšno izmed testiranih kovin, razen Pb in Se. Izračunali smo, koliko g/dan vzorcev, v katerih smo določili prisotnost kovin, bi povprečna odrasla oseba lahko pojedla, da še ne bi presegla postavljenih mej za vnos kovin v telo. Te količine smo primerjali s porcijami podobnih izdelkov iz raziskav. Povprečna odrasla oseba bi z uživanjem škampov, školjk dagenj in govejih jeter v poročanih količinah presegla nekatere meje za vnos As in/ali Cd.
Keywords: ICP-OES, mikrovalovni kislinski razklop, težke kovine, kovine v mesu, kovine v mesnih izdelkih, kovine v morski hrani
Published in DKUM: 02.11.2022; Views: 725; Downloads: 260
.pdf Full text (18,71 MB)

Search done in 0.31 sec.
Back to top
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica