| | SLO | ENG | Piškotki in zasebnost

Večja pisava | Manjša pisava

Iskanje po katalogu digitalne knjižnice Pomoč

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 1 / 1
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Use of a Perth sand penetrometer (PSP) device to determine the engineering parameters of sands
S. D. Mohammadi, 2016, izvirni znanstveni članek

Opis: Determining the in-situ engineering parameters of sandy soils has always been a challenge for geotechnical engineers, resulting in several methods having been developed so far. The Perth Sand Penetrometer (PSP) test is one of the most versatile of these methods. It is a considerably faster and cheaper tool than boring equipment, especially when the depth of the exploration is moderate. In the present research, a methodology for the use of a PSP device to evaluate the engineering parameters of sandy soils in laboratory conditions is discussed and the repeatability of the test results is studied. First of all, the tests were performed on typical Tehran young alluvial deposits (poorly graded sandy soil, SP) consistently prepared to 5 densities using the sand raining or pluviation technique. Next, the normal and logNormal distributions of the test data using the Kolmogorov-Smirnov normality test were examined. After that, based on the obtained results, the relationship types between the dynamic point resistance index (qd) and other parameters, such as the relative density (Dr), the modulus of elasticity (E), the shear modulus (G) and the friction angle of the soil, were determined. The results show that the obtained relationships were semi-logarithmic and logarithmic, and most of the obtained experimental formulas had a high coefficient of determination (>90%). To evaluate the accuracy of the results, 95% confidence and prediction bands were also used and the results show that all the obtained experimental relationships were appropriate. Finally, the repeatability of the test results was evaluated by calculating the coefficient of variations, which was less than 30% for all the tests.
Ključne besede: dynamic-point resistance index (qd), engineering parameters, repeatability, statistical methods
Objavljeno v DKUM: 18.06.2018; Ogledov: 1118; Prenosov: 224
.pdf Celotno besedilo (580,07 KB)
Gradivo ima več datotek! Več...

Iskanje izvedeno v 0.04 sek.
Na vrh
Logotipi partnerjev Univerza v Mariboru Univerza v Ljubljani Univerza na Primorskem Univerza v Novi Gorici