1.
Enhancing racking stiffness in tall timber buildings using double-skin façades : a numerical investigation
Erika Kozem Šilih, Miroslav Premrov, 2025, izvirni znanstveni članek

Opis: The main goal of the paper is to present possible benefits in application of previously developed innovative in-plane load-bearing timber double-skin façade elements (DSF) as additional bracing elements in tall timber buildings. Therefore, a six-storey prefabricated timber structure of a height of 15 m and with a regular floor-plan is analysed by a seismic excitation of ag = 0.225 · g with a strong asymmetrical position of transparent façade elements. Two structural solutions are analysed: a hybrid system combining CLT and Light Timber-Framed walls and a non-hybrid structure made entirely of CLT. In both cases, DSF elements are first considered non-resisting and later as racking-resisting bracing elements. Numerical results show that using racking-resisting DSF elements in a hybrid system (CLT+LTF) achieves a similar increase in overall racking stiffness as a non-hybrid CLT structure with non-resisting DSF. Previous studies highlight hybrid timber systems as the preferred approach due to structural, energy-efficient, and ecological advantages. This finding is significant, offering practical benefits and new design opportunities for modern tall timber buildings with asymmetrical transparent façades, improving both energy efficiency and interior illumination in contemporary prefabricated structures.
Ključne besede: timber, glass, double-skin façades, racking resistance, mathematical modelling, tall timber buildings, seismic design
Objavljeno v DKUM: 18.08.2025; Ogledov: 0; Prenosov: 3
.pdf Celotno besedilo (1,66 MB)
Gradivo ima več datotek! Več...
Gradivo je zbirka in zajema 1 gradivo!

2.
Numerical study of racking resistance of timber-made double-skin façade elements
Erika Kozem Šilih, Miroslav Premrov, 2022, izvirni znanstveni članek

Opis: The use of a double-skin façade (DSF) is a quite new approach in the building renovation process, complementing conventional renovation strategies. A double-skin façade is an envelope wall construction that consists of two transparent surfaces separated by a cavity and can essentially improve the thermal and acoustic resistance of the building envelope. The main double-skin wall components are usually composed of a hardened external single glazing pane and a double or triple thermal insulating internal glass pane, which are connected to the frame structure. Recently, many studies have analysed the thermal and acoustic performance of DSF elements, but almost none in terms of structural behaviour, especially in terms of determining the racking resistance of such wall elements. Moreover, with a view to reduce the global warming potential, an eco-friendly timber frame instead of a commonly used steel, aluminium or plastic frame is studied in this analysis. However, structurally combining timber and glass to develop an appropriate load-bearing structural element is a very complex process involving a combination of two materials with different material properties, where the type of bonding can be selected as a crucial parameter affecting the racking resistance range. Since the costs of experiments performed on such full-scale DSF elements are very high and such experiments are time-consuming, it is crucial to develop special mathematical models for analysing the influence of the most important parameters. Therefore, the main goal of this paper is to develop the finite element mathematical model of the studied DSF structural elements with a highly ecological solution by using a timber frame. In the second step, the developed model is further implemented in the numerical analysis of racking stiffness and followed by a comprehensive parametric numerical study on different parameters influencing the horizontal load-bearing capacity of such DSF timber elements. The obtained results indicate that the new approach of the developed load-bearing prefabricated timber DSF elements can essentially improve racking resistance and stiffness compared with the widely studied timber-glass single-skin wall elements and can thus be fully recommended especially in the structural renovation process of old buildings.
Ključne besede: timber, glass, double-skin façades, racking resistance, mathematical modelling, numerical analysis, Finite Elements Methods (FEM)
Objavljeno v DKUM: 11.03.2025; Ogledov: 0; Prenosov: 7