1.
Emergency gate vibration of the pipe-turbine model
Andrej Predin, Roman Klasinc, 2000, original scientific article

Abstract: The vibration behaviour of an emergency gate situated on a horizontal-shaft Kaplan turbine is studied. The analysis and transfer of the dynamic movements of the gate are quite complex. In particular the behaviour is examined of the emergency gate for the case when the power unit is disconnected from the system or there is a breakdown of the guide vane system at the moment when the maximal head and capacity are achieved. Experimental-numerical methods both in the time domain and in the frequency are employed. Natural vibrations characterize a first zone, corresponding to relatively small gate openings. As the gate opening increases, the vibration behaviour of the gate becomes increasingly dependent on the swirl pulsations in the draft tube of the turbine. Finally, the data transfer from the model to the prototype by use of the dinamic similitude law is discussed.
Keywords: water turbines, emergency gates, vibrations, vibration measurement