Hydroxyapatite coatings on Cp-Titanium Grade-2 surfaces prepared with plasma spraying
Rebeka Rudolf, Dragoslav Stamenković, Zoran Aleksić, Monika Jenko, Igor Đorđević, Aleksandar Todorović, Vukoman Jokanović, Karlo Raić, 2015, original scientific article

Abstract: Thin hydroxyapatite coatings were produced on Cp-Titanium Grade-2 samples, with new high-voltage pulse-power equipment PJ-100 (Plasma Jet, Serbia) in order to get a more stable implant structure appropriate for further clinical applications. A comparative analysis of differently prepared surfaces of the Cp-Titanium Grade-2 samples was done before the hydroxyapatite was applied. Microstructural observation of the modified hydroxyapatite/implant surface was done using scanning-electron-microscopy imaging and Auger electron spectroscopy, with the aim of detecting the morphology and the elements contained in the new surfaces of the samples. The results confirmed that the surface of Cp-Titanium Grade-2 modified with hydroxyapatite is very similar to the bone structure.
Keywords: Cp-Ti2 material, hydroxyapatite, plasma, characterization
Published: 16.03.2017; Views: 464; Downloads: 46
.pdf Full text (1,94 MB)
This document has many files! More...

2.
Mechanical properties of the materials for bruxoguards
Vojkan Lazić, Aleksandra Špadijer Gostović, Nebojša Romčević, Igor Đorđević, Ana Todorović, Rebeka Rudolf, 2014, original scientific article

Abstract: The aim of this study is to investigate the mechanical properties of polymethyl methacrylate (PMMA) and thermoplastic polycarbonate (TPC) materials in order to produce night bruxoguards. For this purpose we used a static tensile test. In the next step the microstructures of PMMA and TPC were observed. Within this framework special attention was paid to the examination of the tensile-test tube fracture surfaces for both materials. This approach revealed that PMMA is a brittle and TPC is a plastic material. Certain mechanical properties and a review of the crucial areas confirmed that the TPC material is extremely favourable for making occlusal splints.
Keywords: polymers, mechanical properties, characterization, bruxoguards, polymethyl methacrylate, thermoplastic polycarbonate
Published: 16.03.2017; Views: 472; Downloads: 55
.pdf Full text (348,98 KB)
This document has many files! More...

3.
Synthesis and characterization of hardened Cu-Fe-Ni-P alloy
Goran Brovč, Goran Dražić, Blaž Karpe, Igor Đorđević, Gorazd Lojen, Borut Kosec, Milan Bizjak, 2015, original scientific article

Abstract: In the manufacturing industry of electrical contacts, the prohibition of the use of toxic metals (Cd, Be), and desire to avoid the alloying with precious metals (Ag) has created a need for new alloys with good electrical conductivity and high mechanical properties at elevated temperatures. As a potentially useful material for this purpose, we have analyzed the continuously cast Cu-Fe-Ni-P alloy in various heat treatment conditions. Sequence of phase transformations during heat treatment was followed by 4 point D.C. electrical resistivity measuring method, and analyzed by scanning (SEM) and transmission (TEM) electron microscopy. Measurements of Vickers hardness and electrical conductivity after various heat treatment procedures indicate on high potential of Cu-Fe-Ni-P alloys as a material for electrical contacts.
Keywords: copper alloys, precipitation hardening, electrical contacts, electrical conductivity